Shower wall with the valve and trim positions set during tile work

With the framing repaired and dry in Part 4, the plumbing goes in. This is the stage that decides how the shower feels every morning: water temperature, pressure and where the water lands. It is also the stage that is hardest to change later, because everything is inside the wall.

Step 1: Choose the valve type

Every valve must be paired with the trim made for it. The valve body and the trim are bought together.

Step 2: Set the valve at the right depth

This is the detail most often done wrong. Every valve has a range of wall thickness it can accept, measured from the valve body to the finished tile surface. The finished wall in a modern shower is the backer board, the waterproofing and the tile with its mortar. If the valve sits too deep, the trim does not reach. Too shallow, and the trim stands off the wall and leaves a gap for water.

We calculate the total finished thickness from the actual backer and tile, then mount the valve on solid blocking at the depth the manufacturer specifies, using the plaster guard that comes with the valve as a depth gauge.

Step 3: Heights and positions

Typical heights, adjusted to the family and the layout:

In a walk-in shower, placing the valve near the entry, away from the shower head, lets you turn the water on without getting wet.

Step 4: Supply lines

We run new supply lines from the existing branch to the valve, the vanity and the toilet. In most remodels we use PEX or copper. Old galvanized pipes found during demolition, which narrow inside with corrosion and lower the pressure, are replaced back to a sound connection. Lines are strapped to the framing so they do not knock when valves close.

Step 5: Drains and vents

Step 6: Blocking while the walls are open

Before the walls close, we add solid wood blocking between the studs for:

Step 7: Test before the walls close

Then the valve gets its plaster guard back on, and the rough-in is photographed with a tape measure in the frame, so we always know where every pipe is behind the tile.

Frequently asked questions

Why does the shower valve depth matter?

The trim only fits a certain wall thickness. A valve set too deep or too shallow leaves the trim loose or short, and that gap lets water into the wall.

Pressure balance or thermostatic valve?

Pressure balance for a standard shower. Thermostatic for showers with several outlets or when exact temperature control matters.

How high should a shower head be?

Usually between 78 and 84 inches from the floor, adjusted to the family.

Should I add blocking for grab bars even if I do not need them now?

Yes. It is inexpensive while the walls are open and saves opening tile later.

What comes next

In Part 6 we cover what happens when the layout changes: moving a toilet or a drain on a concrete slab.

Planning a bathroom remodel in Boca Raton or nearby? See our bathroom remodeling page or schedule a site visit with Edgar at stronghandsflpro.com/contact or (754) 261-2153.