With the framing repaired and dry in Part 4, the plumbing goes in. This is the stage that decides how the shower feels every morning: water temperature, pressure and where the water lands. It is also the stage that is hardest to change later, because everything is inside the wall.
Step 1: Choose the valve type
- Pressure balance valve. The most common type. It keeps the hot and cold mix balanced when pressure changes, for example when someone flushes a toilet, so the shower does not suddenly turn scalding or cold. One handle controls temperature and usually flow.
- Thermostatic valve. It keeps the set temperature, not just the balance, and usually has separate controls for temperature and volume. It is the better choice for showers with several outlets, such as a rain head plus a hand shower and body sprays, because it handles higher flow.
- Diverters. With more than one outlet, a diverter or a multi-port valve sends water to the head, the hand shower or both.
Every valve must be paired with the trim made for it. The valve body and the trim are bought together.
Step 2: Set the valve at the right depth
This is the detail most often done wrong. Every valve has a range of wall thickness it can accept, measured from the valve body to the finished tile surface. The finished wall in a modern shower is the backer board, the waterproofing and the tile with its mortar. If the valve sits too deep, the trim does not reach. Too shallow, and the trim stands off the wall and leaves a gap for water.
We calculate the total finished thickness from the actual backer and tile, then mount the valve on solid blocking at the depth the manufacturer specifies, using the plaster guard that comes with the valve as a depth gauge.
Step 3: Heights and positions
Typical heights, adjusted to the family and the layout:
- Valve: about 38 to 48 inches from the shower floor, reachable from outside the water spray when possible.
- Shower head: usually 78 to 84 inches, higher for a tall family or a rain head from the ceiling.
- Hand shower: on a slide bar or a fixed holder within reach of a bench.
- Tub spout, if there is a tub: positioned so it clears the tub rim.
In a walk-in shower, placing the valve near the entry, away from the shower head, lets you turn the water on without getting wet.
Step 4: Supply lines
We run new supply lines from the existing branch to the valve, the vanity and the toilet. In most remodels we use PEX or copper. Old galvanized pipes found during demolition, which narrow inside with corrosion and lower the pressure, are replaced back to a sound connection. Lines are strapped to the framing so they do not knock when valves close.
Step 5: Drains and vents
- Shower drain. The drain location is set by the shower pan design in Part 8, whether a center drain or a linear drain.
- Vanity drain. Set at the right height for the vanity and sink, usually around 18 to 20 inches from the floor.
- Toilet flange. The rough-in distance from the finished wall to the center of the drain, usually 12 inches, matches the toilet model.
- Venting. Every fixture drain needs a vent so it drains smoothly and the trap keeps its water seal. We confirm the existing vents are adequate for any changes.
Step 6: Blocking while the walls are open
Before the walls close, we add solid wood blocking between the studs for:
- Grab bars, even if they will be installed later. Blocking now costs little. Opening a tiled wall later costs a lot.
- The shower glass hinges and panels, which need solid backing.
- The vanity, mirror and towel bars.
- The niche framing, at the height and width chosen in Part 1.
- A bench, if the design has one.
Step 7: Test before the walls close
- Pressure test. The new supply lines are capped and pressurized, and the reading is watched for a drop over time. A drop means a leak.
- Drain test. Drains are filled or run with water and checked for leaks at every joint.
- Inspection, when the work requires one, happens at this stage, with the walls still open.
Then the valve gets its plaster guard back on, and the rough-in is photographed with a tape measure in the frame, so we always know where every pipe is behind the tile.
Frequently asked questions
Why does the shower valve depth matter?
The trim only fits a certain wall thickness. A valve set too deep or too shallow leaves the trim loose or short, and that gap lets water into the wall.
Pressure balance or thermostatic valve?
Pressure balance for a standard shower. Thermostatic for showers with several outlets or when exact temperature control matters.
How high should a shower head be?
Usually between 78 and 84 inches from the floor, adjusted to the family.
Should I add blocking for grab bars even if I do not need them now?
Yes. It is inexpensive while the walls are open and saves opening tile later.
What comes next
In Part 6 we cover what happens when the layout changes: moving a toilet or a drain on a concrete slab.
Planning a bathroom remodel in Boca Raton or nearby? See our bathroom remodeling page or schedule a site visit with Edgar at stronghandsflpro.com/contact or (754) 261-2153.